English
Language : 

VE-J01-CY Datasheet, PDF (3/6 Pages) Vicor Corporation – Half Brick, DC-DC Converters
CONVERTER SPECIFICATIONS (cont.)
VI-J00, VE-J00
OUTPUT CHARACTERISTICS
Parameter
Setpoint accuracy
Load/line regulation
Output temperature drift
Long term drift
Output ripple – pp:
2 V, 3.3 V
5V
10 – 95 V
Trim range[a]
Total remote
sense compensation
Current limit
Short circuit current
VI-J00 E-Grade
Min
Typ
Max
1%
2%
0.5%
1%
0.02
0.02
50%
0.5
105%
105%
200
5%
3%
110%
135%
140%
VI-J00 C-, I-, M-Grade
Min
Typ
Max
0.5%
1%
0.05%
0.2%
0.2%
0.5%
0.01
0.02
0.02
50%
0.5
105%
105%
100
2%
0.75%
150
3%
1.5%
110%
125%
130%
[a] 10 V, 12 V, 13.8 V, 15 V outputs, or “V” input range have standard trim range ±10%. Consult factory for wider trim range.
95 V output –50 + 0% trim range.
Units Test Conditions
VNOM
VNOM LL to HL, 10% to Full Load
VNOM
LL to HL, No Load to 10%
% / °C Over rated temperature
%/1K hours
mV
VNOM
VNOM
VNOM
Volts
Ifull load
Ifull load
20 MHz bandwidth
20 MHz bandwidth
20 MHz bandwidth
0.25 V max. neg. leg
Automatic restart
Automatic restart
CONTROL PIN SPECIFICATIONS
Parameter
Gate out impedance
Gate in impedance
Gate in high threshold
Gate in low threshold
Gate in low current
VI-J00 E-Grade
Min
Typ
Max
50
1000
6
0.65
6
VI-J00 C-, I-, M-Grade
Min
Typ
Max
50
1000
6
0.65
6
Units
Ohms
Ohms
Volts
Volts
mA
Test Conditions
Use open collector
VI-J00 DC-DC Converters
Page 3 of 6
Rev 2.8
10/2013
vicorpower.com
800 927.9474