English
Language : 

I048C030T015P2 Datasheet, PDF (3/8 Pages) Vicor Corporation – Intermediate Bus Converters Quarter-Brick, 48 Vin Family
PRELIMINARY
ELECTRICAL CHARACTERISTICS
For comprehensive data on any of the configurations, please refer to the data sheet for the BCM with output voltage (K Factor) of
the Intermediate Bus Converter of interest. Data sheets are available from our website at www.vicorpower.com.
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and case temperature,
unless otherwise specified.
INPUT SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Operating input voltage
38
48
55
Vdc
Input surge withstand
100
Vdc
Undervoltage
Turn-on
Turn-off
36.1
38
Vdc
32.6
33.8
Vdc
Overvoltage
Turn-off
Turn-on
55.0
Vdc
59
Vdc
Input reflected ripple current
3
% Iin
Input dV/dt
10
V/µs
Turn-on time
Power up
PC enable
300
ms
50
µs
No load power dissipation
2.5
W
Recommended external
10
50
µF
input capacitance
Notes
12 V 200 W & 400 W units are 42–53 Vdc
<100ms
mA p-p with recommended external input capacitor
per BCM
200 nH maximum source inductance
OUTPUT SPECIFICATIONS
Parameter
Min
Output voltage accuracy
Peak repetitive output current
Current limit
Average short circuit current
Efficiency
Output OVP setpoint
Line regulation
Load regulation
Temperature regulation
Ripple and noise, p-p
Switching frequency
Power sharing accuracy
Transient response
Voltage deviation
Response time
Recovery time
Typ
±2
125
200
96.0
120
±0.05
100
3.5
±5
2
200
1
Max
Unit
%
150
%
%
mA
%
%
% / °C
mV
MHz
±10
%
%
ns
µs
Notes
48 V input; no load; 25°C
<1 ms; see note 2 below
See note 1 below
48 Vin; full load; 25°C
Fixed ratio; Vout = Vin•K (see product matrix)
∆Vout = ∆Iout•Rout (see product matrix)
48 Vin; full load; 20 MHz bandwidth
Fixed
10 to 100% load
No load - full load step change, see note 2 below
Note 1: Current limit parameter does not apply for all models. Please see product matrix on page 2 for exceptions.
Note 2: For important information relative to applications where the unit is subjected to continuous dynamic loading, contact Vicor
applications engineering at 800-927-9474.
Factorized Power
Vicor Corporation Tel: 800-735-6200 vicorpower.com Quarter-Brick Intermediate Bus Converters
Rev. 1.3
Page 3 of 8