2.0 ELECTRICAL CHARACTERISTICS (CONT.)
ATTRIBUTE
SYMBOL
CONDITIONS / NOTES
MIN
PROTECTION
Input overvoltage lockout threshold
Input overvoltage recovery threshold
VIN_OVLO+
VIN_OVLO-
Input overvoltage lockout hysteresis
VIN_OVLO_HYST
Overvoltage lockout response time
TOVLO
Fault recovery time
TAUTO_RESTART
Input undervoltage lockout threshold
VIN_UVLO-
Input undervoltage recovery threshold VIN_UVLO+
Input undervoltage lockout hysteresis VIN_UVLO_HYST
Undervoltage lockout response time
TUVLO
Output overcurrent trip threshold
IOCP
Output overcurrent response time constant
TOCP
Effective internal RC filter
Short circuit protection trip threshold
ISCP
Short circuit protection response time
TSCP
Thermal shutdown threshold
TJ_OTP
55.1
55.0
240
28.5
28.5
30
63
125
B048x096y24A
TYP
MAX
UNIT
58.5
62
V
57.2
58
V
1.2
V
8
µs
300
380
ms
31.1
37.4
V
33.7
37.4
V
1.6
V
8
µs
39
55
A
3.8
ms
A
1
µs
ºC
Safe Operating Area Average & Peak
300
100
250
80
200
60
150
40
100
20
50
7.0
8.0
9.0
10.0
Output Voltage (V)
0
11.0
P (ave)
P (pk), < 10 ms
I (ave)
I (pk), < 10 ms
Figure 1 — Safe operating area
BCM® Bus Converter
Page 3 of 18
Rev 1.1
08/2014
vicorpower.com
800 927.9474