SPECIFICATIONS
All specifications valid at 48 VIN , 100% rated load and 25°C ambient, unless otherwise indicated.
Electrical Characteristics
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
INPUT (Operating from DC input source)
Operating input voltage
Non-operating input surge withstand
Operating input dV/dt
Undervoltage protection
Turn-on
Turn-off
Turn-on/ Turn-off hysteresis
Time constant
Overvoltage protection
Turn-off
Turn-on
Time constant
Turn ON delay
Start up inhibit
Turn-on delay
Output voltage rise time
Restart turn-on delay
No Load power dissipation
Enabled
Disabled
Input current
Inrush current overshoot
Input reflected ripple current
Peak short circuit input current
Repetitive short circuit peak current
Internal input capacitance
Internal input inductance
Recommended external
input capacitance
38
<100 mS
33
31
2
60
55
VIN reaching turn-on voltage
to enable function operational, see Figure 6
Enable to 10% VOUT; pre-applied VIN, see Figure 7,
0 load capacitance
From 10% to 90% Vout, 10% load,
0 load capacitance.
See page 10 for resart after EN pin disable
Low line, full load
Using test circuit in Figure 21
At max power;
Using test circuit in Figure 22
200 nH maximum source inductance
47
48
55
Vdc
75
Vdc
5
V/us
38
Vdc
36
Vdc
Vdc
7
µs
64
Vdc
64
Vdc
4
µs
15
ms
50
µs
50
µs
2000
ms
2.1
2.5
W
0.12
0.15
W
8.2
A
15
A
300
mArms
30
A
25
A
8.8
µF
5
nH
470
µF
OUTPUT
DC Output voltage band
Output power [a]
36-60 VIN
Output current
Output start up load
Effective output resistance
Line regulation (K factor)
Current share accuracy
No load, over Vin range
Pout ≤ 300 W
of Iout max, maximum output capacitance
VOUT = K • VIN @ no load
Full power operation; See Parallel Operation
on page 11; up to 3 units
7.6
9.6
11.0
V
0
300
W
40
A
15
%
5.3
mΩ
0.198
0.200 0.2020
10
%
[a] Does not exceed IPC-9592 derating guidelines. At 70°C ambient, full power operation may exceed IPC -9592 guidelines, but does not exceed