English
Language : 

FARM1C11_15 Datasheet, PDF (2/11 Pages) Vicor Corporation – Autoranging Rectifier Module Up to 1000 Watts
FARMxxxx
ELECTRICAL CHARACTERISTICS
Electrical characteristics apply over the full operating range of input voltage, output power and baseplate temperature, unless
otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate. Specifications apply for AC
mains having up to 5% total harmonic distortion.
INPUT SPECIFICATIONS (FARM1xxx, FARM2xxx)
Parameter
Min
Typ
Max
Operating input voltage
low range
90
132
high range
180
264
Input undervoltage
90
47
63
AC line frequency
47
880
Power factor
0.60
Inrush current
30
Unit
Vac
Vac
Vac
Hz
Hz
Amps
Notes
Autoranging (doubler mode)
Autoranging (bridge mode)
No damage
C-Grade
T-Grade, H-Grade
Dependent on line source impedance, hold up
capacitance and load.
264 Vac peak line
OUTPUT SPECIFICATIONS
Parameter
Output power
Efficiency
Output voltage
FARM1xxx
Min
Typ Max
0
500
0
750
94
96
250
370
External hold-up capacitance
1,100
FARM2xxx
Min
Typ
Max
0
750
0
1000
94
96
250
370
1,750
Unit
Watts
Watts
%
Vdc
µF
µF
Notes
90 – 132 Vac
180 – 264 Vac
120/240 Vac
90 – 264 Vac
2 - 3,300 µF in series; HUB3300-S
2 - 2,200 µF in series; HUB2200-S
CONTROL PIN SPECIFICATIONS
Parameter
Min
Typ
Max
AC Bus OK (B OK)
Low state resistance
15
Low state voltage
0.1
High state voltage
14.0
15.0
15.4
B OK true threshold
235
240
245
B OK false threshold
200
205
210
Module Enable (EN)
Low state resistance
15
Low state voltage
0.1
High state voltage
12
14
16
Enable threshold
235
240
245
Disable threshold
185
190
195
AC Bus OK - Module Enable,
12
14
16
differential error*
* Tracking error between BUS OK and Enable thresholds
FARM™
Page 2 of 11
Rev 6.7
06/2015
Unit
Notes
Ω
To negative output – Bus normal
Vdc
Bus normal 50 mA max.
Vdc
Bus abnormal, 27 K internal pull up to 15 Vdc (see Fig.11)
Vdc
Output Bus voltage (see Fig. 8)
Vdc
Output Bus voltage
Ω
To negative output – Converters disabled
Vdc
50 mA max.
Vdc
150 K internal pull up to 15 Vdc (see Fig. 10)
Vdc
Output bus voltage (see Fig. 8)
Vdc
Output bus voltage
Vdc
AC Bus OK and Module Enable thresholds track
vicorpower.com