PRM48Bx480y600A00
80
60 I
Compensation Gain
40
E
F
PRM Open Loop Min Load
A
20
PRM Open Loop Max Load
0
Open Loop Gain vs. Frequency
10MHz GBW
B
J
FCMIN FCMAX
K
L
-20
C
-40
G
Frequency (Hz)
Figure 27 – reference asymptotic Bode plot for the considered system
10.2.6 High Frequency Pole Design (C2):
Using Equation [3], C2 should be selected so that FP2 is
at least one decade above FCMAX and prior to the gain
bandwidth product of the operational amplifier (10MHz
for this example). For applications with a higher desired
crossover frequency the use of a high gain bandwidth
product amplifier may be necessary to ensure that the
real pole can be set at least one decade above the
maximum crossover frequency.
10.2.7 Verifying Stability:
The preferred method for verifying stability is to use a
network analyzer, measuring the closed loop response
across various lines and load conditions.
In the absence of a network analyzer, a load step
transient response can be used in order to estimate
stability.
Figure 28 illustrates an example of a load step response.
Equation [4] can be used to predict the phase margin
based on the ratio of the “kick” to “droop” (as defined in
Fig. 28).
Figure 28 – load step response example and “droop”
vs. “kick” definition
PRM® Regulator
Page 19 of 22