General Characteristics (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TCASE
≤100°C (T-Grade); All other specifications are at TCASE = 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Isolation capacitance
Isolation resistance
MTBF
Agency approvals / standards
CHI_LO
RHI_LO
Safety
Unpowered unit
620
780
940
At 500VDC
10
MIL-HDBK-217Plus Parts Count - 25°C
Ground Benign, Stationary, Indoors /
3.53
Computer
Telcordia Issue 2 - Method I Case III;
25°C Ground Benign, Controlled
3.90
cTÜVus “EN 60950-1”
cURus “UL 60950-1”
CE Marked for Low Voltage Directive and RoHS Recast Directive, as applicable
pF
MΩ
MHrs
MHrs
BCM® in a VIA Package
Page 16 of 40
Rev 1.1
05/2016
vicorpower.com
800 927.9474