English
Language : 

IB0XXQ120T53XX-XX Datasheet, PDF (12/19 Pages) Vicor Corporation – 4:1 Intermediate Bus Converter Module: Up to 650W Output
Application Characteristics: Waveforms (Cont.)
IB0xxQ120T53xx-xx
Figure 18 — Two modules parallel array test. VOUT and IIN
change when one module is disabled. Nominal VIN,
IOUT = 53A
60
50
40
30
20
10
0
20
30
40
50
60
70
Ambient Temperature (°C)
200LFM
400LFM
80
90
600LFM
Figure 20 — Maximum output current derating vs. ambient air
temperature. Transverse airflow. Board and junction
temperatures within IPC-9592 derating guidelines
700
600
500
400
300
200
100
0
36
40
44
48
50
52
54
Input Voltage (VDC)
Figure 19 — Two modules parallel array test. VOUT and IIN
change when one module is enabled. Nominal VIN,
IOUT = 53A
60
50
40
30
20
10
0
20
30
40
50
60
70
Ambient Temperature (°C)
200LFM
400LFM
80
90
600LFM
Figure 21 — Maximum output current derating vs. ambient air
temperature. Longitudinal airflow. Board and
junction temperatures within IPC-9592
derating guidelines
Figure 22 — Maximum output ower vs. input voltage
IBC Module
Page 12 of 19
Rev 1.1
09/2016
vicorpower.com
800 927.9474