PRM48AH480X200A00 Datasheet, PDF (10/42 Pages) Vicor Corporation – Pin selectable operating mode | |||
|
◁ |
PRM48AH480x200A00
Signal Speciï¬cations (cont.)
Specifications apply over all line and load conditions, TINT = 25ºC and output voltage from 20.0 V to 55.0 V, unless otherwise noted.
Boldface specifications apply over the temperature range of -40ºC < TINT < 125ºC (T-grade).
SGND: Signal Ground
⢠All control signals must be referenced to this pin, with the exception of VC
⢠SGND is internally connected to -IN and -OUT
Signal Type
State
Attribute
Symbol
Conditions / Notes
Analog Input / Output
Maximum Allowable
Any
Current
ISGND
Min
Typ
-100
Max
100
Unit
mA
TRIM
⢠TRIM is used to select operating mode and trim the output voltage in Adaptive Loop Operation
⢠Internal pullup to VCC_INT through 10 k⦠resistor
⢠When pulled below 0.45 V during power up, Remote Sense / Slave Operation is selected
⢠When allowed to pull up above 0.55 V during power up, Adaptive Loop Operation is selected
⢠Operating mode is detected during power up and cannot be changed unless input power is cycled
Signal Type
State
Normal
Attribute
Internally Generated
VCC
Symbol
VCC_INT
Conditions / Notes
Analog Input
Operation
Internal Pullup
Resistance to VCC_INT
Mode Detection
Delay
RTRIM_INT 0.5% tolerance resistor
From ENABLE high to mode detected,
tMODE_DETECT
after VIN ï¬rst applied
Mode
Detect
Remote Sense
Enable Threshold
VRS_MODE_EN
Pull below this value during ï¬rst
start up after application of power to
enable Remote Sense / Slave Operation
Remote Sense
Disable Threshold
VRS_MODE_DIS
Pull above this value during ï¬rst
start up after application of power to
enable Adaptive Loop Operation
Min
3.20
9.83
100
0.45
Typ
3.28
10.00
140
Max
3.36
10.18
200
0.55
Unit
V
kâ¦
µs
V
V
PRMTM Regulator
Page 10 of 42
Rev 1.5
11/2015
vicorpower.com
800 927.9474
|
▷ |