PI3311-01-LGIZ Datasheet, PDF (10/26 Pages) Vicor Corporation – 8V to 36Vin, 15A Cool-Power ZVS Buck Regulator
PI33XX-X1
PI3318-X1 (1.8 Vout) Electrical Characteristics
Specifications apply for -40C < TJ < 125C, Vin =24V, L1=125nH (Note 1) unless other conditions are noted.
Parameter
Timing
Switching Frequency
Fault Restart Delay
Sync In (SYNCI)
Symbol
fS
tFR_DLY
Synchronization Frequency Range
SYNCI Threshold
Sync Out (SYNCO)
SYNCO High
SYNCO Low
SYNCO Rise Time
SYNCO Fall Time
Soft Start And Tracking
∆fSYNCI
VSYNCI
VSYNCO_HI
VSYNCO_LO
tSYNCO_RT
tSYNCO_FT
TRK Active Input Range
VTRK
TRK Max Output Voltage
TRK Disable Threshold
Charge Current (Soft – Start)
Discharge Current (Fault)
Soft-Start Time
Enable
VTRK_MAX
VTRK_OV
ITRK
ITRK_DIS
tSS
High Threshold
VEN_HI
Low Threshold
VEN_LO
Threshold Hysteresis
VEN_HYS
Enable Pull-Up Voltage
(floating, unfaulted)
VEN_PU
Enable Pull-Down Voltage
(floating, faulted)
VEN_PD
Source Current
IEN_SO
Sink Current
IEN_SK
Note 1: All parameters reflect regulator and inductor system
performance. Measurements were made using a standard PI33XX
evaluation board with 3x4” dimensions and 4 layer, 2oz copper.
Refer to inductor pairing table within Application Description
section for specific inductor manufacturer and value.
Note 2: Regulator is assured to meet performance specifications
by design, test correlation, characterization, and/or statistical
process control.
Min Typ Max Units Conditions
550
kHz Note 6.
30
ms
50
110
%
Relative to set switching
frequency. Note 3.
2.5
V
4.5
V Source 1mA
0.5
V Sink 1mA
10
ns 20pF load
10
ns 20pF load
0
1.04
V
Internal reference
tracking range.
1.2
V
20
40
60
mV
-70
-50
-30
µA
6.8
mA
2.2
ms CTRK = 0uF
0.9
1
1.1
V
0.7
0.8
0.9
V
100 200 300 mV
2
V
0
V
-50
µA
50
µA
Note 3: Output current capability may be limited and other
performance may vary from noted electrical characteristics when
switching frequency or Vout is modified.
Note 4: Refer to Output Ripple plots.
Note 5: Refer to Load Current vs. Ambient Temperature curves.
Note 6: Refer to Switching Frequency vs. Load current curves.
vicorpower.com
800 735.6200
Rev 1.3
09/2015
Cool-Power®
Page 10 of 26