English
Language : 

VI-IAM Datasheet, PDF (1/2 Pages) Vicor Corporation – Input Attenuator Modules
12 1-800-735-6200
VI-IAM ™
Input Attenuator
Modules
Features
s Inputs: 24, 48 and 300Vdc
s High Surge Withstand:
– Bellcore
– British Telecom BTR 2511
– IEC-60801-5
s EMI/RFI Specifications:
– Bellcore TR-TSY-000513
– British Telecom BTR 2511
– FCC Level “A”
– EN55022 Level “B”
s UL, CSA, TÜV, VDE, BABT
s 97% Efficiency
s Input Reverse Polarity Protection
s Logic Disable
s Expansion Output for Arrays
s Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7)
s CE Marked
Product Highlights
VI-IAM Specifications
(typical at TBP = 25°C, nominal line, 75% load, unless otherwise specified)
PARAMETER
MIN TYP MAX POWER
REMARKS
Input Range/Power Limit
VI-A11-CU
21Vdc 24Vdc 32Vdc 200W Delivered power is
VI-AWW-CU
18Vdc 24Vdc 36Vdc 200W from any combination
VI-A33-CQ
42Vdc 48Vdc 60Vdc 400W of DC-DC converters
VI-ANN-CQ
36Vdc 48Vdc 76Vdc 400W
VI-A66-CQ
200Vdc 300Vdc 400Vdc 400W
Isolation
Size
1,500 VRMS
Input/Output to Base
2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7)
Weight
3.0 Ounces (85 Grams)
EMI/ RFI (conducted
Meets Bellcore TR-TSY-000513, Issue 2, Rev. 1
emissions)
(24 and 48V Input);
British Telecom BTR 2511, Issue 2
(24 and 48V Input);
FCC Part 15, Class A, EN55022 Class B
Transient Protection
Meets Bellcore TA-TSY-001003, Issue 1, 9/89
British Telecom BTR 2511, IEC 61000-4-5 Level 2(VI-A66 only)
Reverse Polarity Protection No damage to unit
Product Grade Specifications
PARAMETER
Storage Temp.
Operating Temp.
(Baseplate)
E
–20°C to +105°C
–10°C to +100°C
PRODUCT GRADE
C
I
–40°C to +105°C –55°C to +105°C
–25°C to +100°C –40°C to +100°C
M
–65°C to +105°C
–55°C to +100°C
The Input Attenuator Module (VI-IAM) is
a component-level, DC input front end
filter designed to occupy minimum board
space while providing maximum protection
for today’s sophisticated electrical
systems. The VI-IAM, in combination
with Vicor 24, 48 and 300Vdc input
modules, provides a highly efficient, high
density power system with outputs from
1 to 95Vdc and power expandable from
25 to 800W. Your system will benefit from
the small size, efficiency and inherent
reliability of Vicor’s component-level
converters, while meeting the toughest
demands of Telecommunications and
Industrial power applications.
This combination provides
compliance with the transient
requirements of Bellcore, British
Telecom and IEC standards, and meets the
EMI/RFI specifications of Bellcore,
British Telecom and FCC Part 15, Subpart
B and EN55022.
Compatible Products
s VI-200 and VI-J00
(Inputs: 1, W, 3, N and 6)
s Mega Modules
(Inputs: 1, W, 3, N and 6)
Note: For alternative product grades, change the “C” in the part number to “E”, “I” or “M”
Long Term Safe Operating Area Curves
(1% duty cycle max., Zs = .5Ω, for short duration transient capability refer to specifications)
Standard
100V
24V Inputs
R.E.
Wide Range
100V
160V
48V Input
R.E.
I.S.W.
Full Load
S.D.
32V
21V
0.1
36V
Normal Operating Area
18V
1 10ms 100 1000
100V
60V
42V
0.1
I.S.W.
Full Load
S.D.
Normal Operating Area
1 10ms 100 1000
48V Wide Range Input
300V Input
276V
R.E.
800V
R.E.
125V
76V
I.S.W.
Full Load
S.D. 100V
Normal Operating Area
S.D.
36V
0.1 1 10ms 100 1000
500 ms
500V
400V
200V
0.1
I.S.W.
Full Load
S.D.
Normal Operating Area
1 10ms 100 1000
500 ms