QPI-2L Datasheet, PDF (1/8 Pages) Vicor Corporation – 12 Amp Active EMI Filter for 24V DC Bus
®
QPI-2L
QuietPower™
12 Amp Active EMI Filter for 24 V DC Bus
Description
The QPI-2 active EMI filter attenuates conducted
common-mode (CM) and differential-mode (DM) noise
over the CISPR22 frequency range of 150 kHz to 30
MHz. The product is designed for use on a 24 Vdc bus
(10-40 Vdc). The QPI-2’s 12 A rating supports multiple
DC-DC converter loads up to a PCB temperature of
60°C. At a 100°C PCB temperature the QPI-2 supports
10 A loads. Designed for a nominal 24 V bus, the QPI-2
supports industrial and COTS applications.
In comparison to passive solutions, the use of active
filtering reduces the volume of the common-mode
choke, providing a low profile, surface mount device.
Smaller size saves valuable board real estate and the
reduced height enhances airflow in blade applications.
The QPI-2 is available in a 1.0" x 1.0" x 0.2" SiP (System
in Package) with LGA mounting. QPI-2-EVAL1 kits are
available for testing the QPI-2. The evaluation board
has a mounted QPI-2 with screw terminals for quick
in-circuit testing.
Check picorpower.com for the QPI-2-EVAL1 evaluation
board and the QPI-AN1 Application Note.
Features
• >55 dB CM attenuation at 250 kHz
• >70 dB DM attenuation at 250 kHz
• 40 Vdc (max input)
• 12 Amp rating
• 100 Vdc surge 100 ms
• 707 Vdc Hi-pot hold off to Shield Plane
• 1.0” x 1.0” x 0.2” SiP (System-in-Package)
• SMT Land Grid Array (LGA)
• -40° to +100°C PCB temperature (See Fig. 5)
• Active filtering reduces volume and height
• Efficiency 99% at full load
• Connect in series for higher attenuation
• TÜV approved
Applications
• Industrial bus supplies
• Telecom base stations
• COTS systems
Typical Application
QPI Performance
RY=10 Ω, 1/4 W
Figure 1 - QPI-2 circuit on input bus.
Picor Corporation • www.picorpower.com
Figure 2 - Attenuation curves showing common-mode and
differential-mode attenuation.