English
Language : 

NBM6123X46C15A6YZZ Datasheet, PDF (1/26 Pages) Vicor Corporation – Non-Isolated, Fixed Ratio DC-DC Converter
Features
• Up to 160A continuous secondary current
• Up to 3600W/in3 power density
• Parallel operation for multi-kW arrays
• OV, OC, UV, short circuit and thermal protection
• 6123​through-hole ChiP package
n 2.402” x 0.990” x 0.286”
(61.00mm x 25.14mm x 7.26mm)
Typical Applications
• DC Power Distribution
• High End Computing Systems
• Automated Test Equipment
• Industrial Systems
• High Density Power Supplies
• Communications Systems
• Transportation
NBM™ Bus Converter
NBM6123x46C15A6yzz
®
S
C
US
C NRTL US
Non-Isolated, Fixed Ratio DC-DC Converter
Product Ratings
VPRI = 42V (36 – 46V)
VSEC = 14V (12.0 – 15.3V)
(no load)
ISEC= up to 160A
K = 1/3
Product Description
The VI Chip® Non-Isolated Bus Converter (NBM™) is a high
efficiency Sine Amplitude Converter™ (SAC™), operating from
a 36 to 46VDC primary bus to deliver a non-isolated, ratiometric
secondary voltage from 12.0 to 15.3VDC.
The NBM6123x46C15A6yzz offers low noise, fast transient
response, and industry leading efficiency and power density. In
addition, it provides an AC impedance beyond the bandwidth of
most downstream regulators, allowing input capacitance normally
located at the input of a POL regulator to be located at the primary
side of the NBM module. With a primary to secondary K factor
of 1/3, that capacitance value can be reduced by a factor of 9x,
resulting in savings of board area, material and total system cost.
Leveraging the thermal and density benefits of Vicor’s ChiP
packaging technology, the NBM module offers flexible thermal
management options with very low top and bottom side thermal
impedances. Thermally-adept ChiP-based power components,
enable customers to achieve low cost power system solutions
with previously unattainable system size, weight and efficiency
attributes, quickly and predictably.
The NBM non-isolated topology allows operation in forward and
reverse directions and provides bidirectional protections. However
if power train is disabled by any protection, and VSEC is present,
then voltage equal to VSEC minus two diode drops will appear on
primary side.
NBM™ Bus Converter
Page 1 of 26
Rev 1.3
09/2016
vicorpower.com
800 927.9474