Product Highlights
The MI-RAM is designed for
applications where extremely low
noise outputs are required. When
used with any Vicor MI-Series
DC-DC converter, the MI-RAM
reduces both line frequency related
ripple and switching noise to less
than 10 mV p-p, DC to 20 MHz.
The combination of the MI-RAM
with an MI converter provides the
output noise performance of a
linear supply at a power density
in excess of 15 W/in3.
All of the features of the MI-Series
converter remain available while
using the MI-RAM, including
output voltage trimming, OVP and
OTP (MI-200 only), current limiting,
remote sense, and output inhibit.
All units are manufactured in ISO
9001-registered facilities. Full
epoxy encapsulation in a low
profile package enables the MI-RAM
to meet MIL-STD-810 environmental
testing requirements.
Attenuation vs. Frequency (typical)
25 db
30 db
35 db
40 db
45 db
50 db
55 db
60 db
10 Hz
100 Hz
1 KHz 10 KHz 100 KHz
Frequency
1 MHz
10 MHz
Input to the converter
(10 V/cm)
Output from the RAM
(2 mV/cm)
MI-RAM 6/05 1 of 1
MI - RAMTM
Military COTS Ripple Attenuator Modules
Features
Reduces output PARD to <10 mV pp
Full attenuation up to 20 A load
Compatible with all MI-Series units
from 5 to 50 Vdc output
No adjustments required
93%-99% efficiency
Converter sense, trim, OV
and OC retained
MIL-STD-810 environments
Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7 mm)
Specifications
(At TBP = 25°C, unless otherwise specified)
PARAMETER
MIN
TYP
MAX
UNITS
NOTES
Output noise and ripple
2.0
3.0
mV pp MI-200; 10% to 100% load
6.0
10.0 mV pp MI-J00; 10% to 100% load
Input voltage range
5Vdc
50
Vdc
Output voltage accuracy
99.5
100.5
%
Of MI source converter
Full load current
10
A
MI-RAM-I1 and MI-RAM-M1
20
A
MI-RAM-I2 and MI-RAM-M2
DC voltage drop
0.34
0.38
10% to full load
Dissipation = (DC voltage drop x load current) + (Vin x 15 mA)
Isolation
250
Vrms
Input/output to baseplate
Weight
3.0 (85)
ounces (grams)
Product Grade Specifications
PARAMETER
PRODUCT GRADE
I - Grade
M- Grade
Storage temperature
Operating temperature (baseplate)
Power cycling burn-in
Temperature cycled with power off
17°C per minute rate of change
Test data supplied at these temperatures*
Warranty
Environmental compliance
-55°C to +125°C
-40°C to +100°C
12 hours, 25 cycles
12 cycles
-65°C to +100°C
-40°C, +80°C
2 years
MIL-STD-810
-65°C to +125°C
-55°C to +100°C
96 hours, 200 cycles
12 cycles
-65°C to +100°C
-55°C, +80°C
2 years
MIL-STD-810
*Test data available for review or download from vicorpower.com
Mechanical Drawing
0.30±0.015
(7,6)±(0,38)
0.49
(12,4)
2.28
(57,9)
1.30
(33,0)
0.65
(16,5)
2.10
(53,4)
0.15
(3,8)
4
9
3
8
MI-RAM 7
2
6
1
5
FULL R
0.15
(3,8)
1.90
(48,3)
0.080 Dia (2) places
Solder plate
over copper alloy
1.40
1.00 (35,6)
0.70 (25,4)
0.40 (17,8)
(10,2)
0.35± 0.015
(8,9)±(0,38)
0.040 (1,0) Dia (7) places
Solder plate
over copper alloy
Product ID
this surface
0.22
(5,6) Min.
0.30
(7,6) Min.
Pin #
1
2
3
4
5
6
7
8
9
Function
+In
+Sense In
–Sense In
–In
+Out
+Sense
NC
–Sense
–Out
2.40
(61,0)
1.75
(44,4) Max.
0.12
(3,0)
0.50 +0.030 (0,76)
(12,7) -0.000 (0)
0.01
Aluminum Base