Features
⢠High efficiency up to 92%
⢠Small Size
⢠High power density (25 W/In3)
⢠Up to 1300 W (Configuration dependent)
⢠Low power standby mode (Green mode)
⢠Universal Input ((47-63 Hz) (400 Hz) (85 to 264 Vac)
⢠DC Input (120 â 300 Vdc)
⢠Up to 4 isolated outputs
⢠Standard 12 V, 14 V, 24 V, 28 V, 36 V & 48 V output
⢠Aux isolated 5 V @ 500 mA bias standby supply
⢠Output parallel capability
⢠All customer interface signals are isolated
Product Description
⢠Output series capability
⢠Output current sharing
⢠MicroPAC to MicroPAC Current sharing
⢠Optional power shed capability
⢠Over temperature warning
⢠Over temperature shut down
⢠Intelligent fan control
⢠Field replaceable fan
⢠Individual output enable / disable
⢠All output enables / disable capability
⢠TTL control signals
⢠Visual LED display panel
⢠External Serial interface and GUI (Part Number CI-01)
The MicroPAC is the ï¬rst Westcor product to utilize Vicorâs VI Chip technology. The power supply uses
BCM modules to provide up to 4 isolated semi regulated output voltages of 12, 14, 24, 28, 36 and 48 Vdc and
up to 1300 W of continuous power in a very small highly eï¬cient package. The isolated outputs may be placed in parallel/series
conï¬gurations and for applications requiring higher power levels MicroPAC power supplies can be conï¬gured in arrays up to
several KW. Safety agency approvals limit the conï¬gured output voltages to 60Vdc. Conï¬gurations and applications where output
voltages are greater than 60Vdc are non-SELV.
This factory conï¬gurable rugged power supply supports a wide range of customer power requirements and is especially suited for
distributed power architectures. The design oï¬ers a small ï¬exible cost eï¬ective solution for applications requiring Power Factor
Correction, high eï¬ciency and power density even in environmentally challenging conditions.
Part Numbering
UP
aâb
b
b
b
c
d
e
MicroPAC
Constant
Number of
outputs,
1 to 4
Output Configuration
Fill in character from chart below for each output
b = Vout Watts b = Vout Watts
A
12
300 G
48 325
B
12
600 H
48 650
C
12
900
I
48 975
D
12 1200 J
48 1300
E
24
600
K
36 900
F
24 1200 T
28 600
P
14
300 U
28 1200
Q
14
600 M
[a]
[a]
R
14
900
Z
[b]
[b]
S
14 1200
[a] M defines a slot with an air block filler, no BCM board
[b] Z indicates the slot is populated with a BCM board that is
connected in series or parallel with the adjacent slot
Cooling
F = Fan
L = -40C Fan
M = Confrontal Coat
Interface Customer Option
Non-Safety Related
S = Standard (TTL levels)
Signaling and Control
RoHS
Compliant
G = RoHS
N = Non-RoHS
Examples:
UP1-FZZZ-FSG
UP4-AAAA-LSN
Denotes a single output of 24 V 1200 W
with a standard fan, standard TTL signaling and control,
RoHS compliant
Denotes 4 output unit, each output is 12 V 300 W.
The fan is a -40°C capable unit, standard TTL signaling,
and the unit is non-RoHS
MicroPAC
Page 1 of 5
Rev 1.2
9/2013