English
Language : 

LINEFILTER Datasheet, PDF (1/2 Pages) Vicor Corporation – For use with VI-HAM
Line Filter
For use with VI-HAM
(P/N 30205)
Features
• Compatible with VI-HAM-xL
and VI-HAM-xM
• RoHS compliant
Product Highlights
The VI-HAM Harmonic Attenuator
Module requires an external filter to meet
international standards for EMI/RFI
emissions, and incorporates transient
surge protection, as outlined in the
specifications below.
4.6 x 2.4 x 1 in
(116,8 x 61,0 x 25,4 mm)
MOV*
P/N 30076
LD
R
Cx
LC
Cy
D1
D2
Cy D3
HAM Filter P/N 30205
Cx = 1.5 uF(x2)SH Cy = 0.01 uF, Y2 type LC = 6.9 mH LD = 0.72 mH
R = 235 KΩ D1,2 = 1.5KE130CA D3 = 1.5KE150CA
*MOV required external to filter to meet normal mode transient surge requirements
Electrical Specifications
Parameter
Min
Typ
Max
Unit
Notes
Operating voltage
85
264
Vac
Operating frequency
47
63
Hz
Operating current (see Figure 1)
6.3
A
Leakage current at 264 Vac, 63 Hz
(Either line to earth)
1.2
mA
Transient surge
1
kV
1.2/50µs pulse as per EN61000-4-5
with external MOV P/N 30076
Withstand
2
joules
0 to 360° phase angle; exceeds IEC 801-5, Level B
Dielectric withstand (line – case)
1500
Vac
Residual voltage after 1 sec.
34
V
General Specifications
Parameter
Min
Typ
Max
Weight
16 (457)
Size
2.4 x 4.6 x 1.0
6,1 x 11,7 x 2,54
Operating temperature (see Figure 1) -20
40
Agency approvals
UL, CSA, TÜV
Unit
oz (g)
in
cm
°C
Notes
Note: The 30205 line filter is not hermetically sealed and therefore should not be subjected to post solder aqueous rinse.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Line Filter
Set your site on VICOR at vicorpower.com
Rev. 1.1
Page 1 of 2