|
DCM3714XD2H26F0YZZ Datasheet, PDF (1/23 Pages) Vicor Corporation – Regulated DC Converter | |||
|
DCM⢠in a VIA Package
DC-DC Converter
DCM3714xD2H26F0yzz
®
C
US
S
C NRTL US
Isolated, Regulated DC Converter
Features & Beneï¬ts
⢠Isolated, regulated DC-to-DC converter
⢠Up to 600 W, 25.00 A continuous
⢠94.0% peak efficiency
⢠309 W/in3 Power density
⢠Wide input range 200 â 420 Vdc
⢠Safety Extra Low Voltage (SELV) 24.0 V Nominal Output
⢠ZVS high frequency switching
⢠Allows remote sense or local sense operation
⢠Tight regulation over all line and load conditions
⢠Fully operational current limit
⢠OV, OC, UV, short circuit and thermal protection
⢠Available in chassis mount and through hole VIA package
n 3.750â x 1.400â x 0.370â
(95.13 mm x 35.5 mm x 9.30 mm)
Product Ratings
VIN = 200 V to 420 V
VOUT = 24.0 V
(21.6 V to 26.4 V Trim)
POUT = 600 W
IOUT = 25.00 A
Product Description
The DCM in a VIA package is an Isolated, Regulated DC-to-DC
Converter, operating from an unregulated, wide range input to
generate an isolated 24.0 Vdc output. With its high frequency
zero voltage switching (ZVS) topology, the DCM converter
consistently delivers high eï¬ciency across the input line range.
The DCM provides tight output voltage regulation and oï¬ers a
secondary-referenced control interface for trim, enable, and
remote sense operation. DCM converters and downstream
DC-DC products support eï¬cient power distribution, providing
superior power system performance and connectivity from a
variety of unregulated power sources to the point-of-load.
The VIA package oï¬ers ï¬exible thermal management options
with very low top and bottom side thermal impedances.
Typical Applications
⢠Industrial
⢠Process control
⢠Automotive
⢠Heavy Equipment
Part Ordering Information
Size:
3.750 x 1.400 x 0.370 in
95.13 x 35.5 x 9.30 mm
Product
Function
Package
Length
Package
Width
Package
Type
Max
Input
Voltage
Range
Ratio
Max Max
Output Output
Voltage Power
Product Grade
(Case Temperature)
Option Field
DCM
37
14
x
D2
H
26
F0
y
z
z
DCM =
DC-DC
Converter
Length in Width in B = Board VIA
Inches x 10 Inches x 10 V = Chassis VIA
Internal Reference
C = -20 to 100°C[1]
T = -40 to 100°C[1]
01 = Chassis/Analog
05 = Short Pin/Analog
09 = Long Pin/Analog
[1] High Temperature Power Derating may apply, see Thermal Speciï¬ed Operating Area, Figure 1 on Page 4.
DCM⢠in a VIA Package
Page 1 of 23
Rev 1.6
03/2016
vicorpower.com
800 927.9474
|
▷ |