English
Language : 

COMPAC Datasheet, PDF (1/4 Pages) Vicor Corporation – DC-DC Switchers 50 to 600W 1-3 Outputs
ComPAC™
Product Highlights
ComPAC delivers up to 600W from
one, two, or three outputs in a package
just 0.99” (25,2mm) in height with the
field proven performance, high
efficiency and high reliability inherent
in Vicor’s component level power
converters. ComPAC meets British
Telecom and European norms for input
surge withstand and meets conducted
emissions of EN55022 Class B.
ComPAC is offered with input voltage
ranges optimized for industrial and
telecommunication applications and
provides extended input overvoltage
capability, input reverse polarity
protection, undervoltage lockout, and
master disable.
Use the configuration chart at the right to define your
Vicor part number(s).
Conduction Cooled Models Available
Add "-CC" to the end of the part number.
(Consult factory for details.)
DC-DC Switchers
50 to 600W
1-3 Outputs
Features
➤ Inputs 24, 48, and 300Vdc
➤ Any output: 1 to 95Vdc
➤ Input surge withstand:
British Telecom BTR 2511,
EN-61000-4-5
➤ Meets British Telecom BTR 2511,
EN55022 Class B conducted emissions
➤ UL, CSA, TÜV (IEC 950)
➤ CE marked
➤ 80-90% efficiency
➤ Up to 10W/cubic inch
➤ Reverse polarity protected
➤ Master disable
➤ Overvoltage shutdown
ComPAC Configuration Chart
Total Power
Part No.
Single Outputs: 50-200W VI-LC
–
100-400W VI-MC
–
300-600W VI-NC
–
Dual Outputs: 100-400W VI-PC
–
150-600W VI-QC
–
Triple Outputs: 150-600W VI-RC
–
Dimensions
8.6" x 2.5" x 0.99"
(218,4 x 63,5 x 25,2mm)
8.6" x 4.9" x 0.99"
(218,4 x 124,5 x 25,2mm)
8.6" x 7.3" x 0.99"
(218,4 x 185,4 x 25,2mm)
8.6" x 4.9" x 0.99"
(218,4 x 124,5 x 25,2mm)
8.6" x 7.3" x 0.99"
(218,4 x 185,4 x 25,2mm)
8.6" x 7.3" x 0.99"
(218,4 x 185,4 x 25,2mm)
Input Voltage
Nominal Range
1 = 24V 21 - 32V (1)
W = 24V 18 - 36V (1)
3 = 48V 42 - 60V (2)
N = 48V 36 - 76V (2)
6 = 300V 200 - 400V (2)
Max
output for
(1)
(2)
≥5V
Outputs
150W
200W
<5V
Outputs
30A
40A
Output Voltage
Z 2V
Y 3.3V
0 5V
X 5.2V
W 5.5V
V 5.8V
T 6.5V
R 7.5V
M 10V K 40V
1 12V 4 48V
P 13.8V H 52V
2 15V F 72V
N 18.5V D 85V
3 24V B 95V
L 28V
J 36V
Product Grade
E = -10°C to +85°C
C = -25°C to +85°C
I = -40°C to +85°C
M = -55°C to +85°C
Output Power/Current
Vout ≥ 5V
W = 100W
V = 150W
U = 200W
S = 300W
Q = 400W
Vout < 5V
20A
30A
40A
60A
80A
Output Power/Current
Vout ≥ 5V
Y = 50W
X = 75W
W = 100W
V = 150W
U = 200W
Vout < 5V
10A
15A
20A
30A
40A
Output Power/Current
Vout ≥ 5V
S = 300W
P = 450W
M = 600W
Vout < 5V
60A
90A
120A
Long Term Safe Operating Area Curves (1% duty cycle max. Zs=0.5Ω; for short duration transient capability refer to page 3.)
160V
100V
60V
42V
0.1
ComPAC
48V Input
R.E.
Standard
100V
24V Inputs
R.E.
Wide Range
100V
276V
48V Wide Range Input
R.E.
800V
300V Input
R.E.
I.S.W.
Full Load
S.D.
Normal Operating Area
1 10ms 100 1000
I.S.W.
Full Load
S.D.
32V
21V
0.1
Normal Operating Area
1 10ms 100
36V
18V
1000
125V
76V
I.S.W.
Full Load
S.D. 100V
Normal Operating Area
S.D.
36V
0.1 1 10ms 100 1000
500ms
500V
400V
200V
0.1
I.S.W.
Full Load
S.D.
Normal Operating Area
1 10ms 100 1000
500ms
I.S.W.: Input surge withstand, no degradation of performance. R.E.: Ratings Exceeded S.D.: Shutdown
10/02 1 of 4