English
Language : 

TFS433R Datasheet, PDF (5/5 Pages) Vectron International, Inc – Filter Specification
tfs433r.doc
VI TELEFILTER
version 3.1
Filter Specification
History
Version Reason of Changes
1.0
- Generate specification according to customer requirements
1.1
- Change pinning according to discussion with customer.
1.2
- Change development specification to preliminary specification.
- Add termination impedances.
- Add typical data.
1.3
- Position of coupling coil changed from pin 7 to pin 3
3.0
- Change starting frequency for 25 dB selection from
fN ± 400 kHz to fN ± 460 kHz.
- Change starting frequency for 40 dB selection from
fN ± 600 kHz to fN ± 660 kHz.
- Change typical values.
- Change termination impedances.
3.1
- Change preliminary specification to filter specification.
24.05.2002
TFS 433 R
5/5
Name
Dr. Wall
Dr. Wall
Dr. Wall
Dr. Wall
Dr. Wall
Date
14.03.2002
21.03.2002
22.04.2002
23.04.2002
29.04.2002
Dr. Wall
24.05.2002
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Vectron International Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is