English
Language : 

TFS360F1 Datasheet, PDF (5/5 Pages) Vectron International, Inc – Filter Specification
tfs360F1.doc
VI TELEFILTER
version 1.4
Filter Specification
TFS 360F1
18.04.2001
5/5
History
Version Reason of Changes
1.0
- Generation of specification
1.1
- Add values for termination impedance and coupling coil
1.2
- Pin numbers in package drawing added
- Tape and reel information added
- Typical filter data added
1.3
- Change values for termination impedances from 520 ohm // -0.85 pF
to 580 Ohm // -0.85 pF.
TFS360F1
1.4
- Increase operating temperature range.
- Change storage temperature range.
- Change value for typical centre frequency.
- Change filter name to TFS360F1
Name
Dr. Wall
Dr. Wall
Dr. Wall
Dr. Wall
Dr. Wall
Date
22.08.2000
28.08.2000
18.10.2000
27.11.2000
18.04.2001
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Vectron International Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.