English
Language : 

TFS141 Datasheet, PDF (5/5 Pages) Vectron International, Inc – Filter Specification
Tfs141.doc
VI TELEFILTER
version 3.0
Filter Specification
TFS 141
09.04.2002
5/5
History
Version Reason of Changes
1.0
Generation of specification according to customer requirements.
1.1
Changed “VSWR” from 11 dBm to 10 dBm
Changed “relative attenuation”
Filter specification
2.0
- terminamting impedance and typical values added
- VSWR definition changed to typical value
3.0
- modifications according to customer requirement
- passband width definition changed to 1,5 dB
- change vibration test conditions to our standard
Name
Pfeiffer
Herrler
Steiner
Steiner
Date
20.06.2001
30.07.2001
21.12.01
09.04.2002
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is