English
Language : 

VS-751 Datasheet, PDF (4/7 Pages) Vectron International, Inc – Dual Frequency VCSO
VS-751 Voltage Controlled SAW Oscillator
Absolute Maximum Ratings
Parameter
Power Supply
Input Current
Output Current
Voltage Control Range
Storage Temperature
Soldering Temperature / Duration
Symbol
VCC
IIN
IOUT
VC
TSTR
TPEAK / tP
Ratings
0 to 6
100
25
0 to VCC
-55 to 125
260 / 40
Unit
V
mA
mA
V
C
C / sec
Stresses in excess of the absolute maximum ratings can permanently damage the device. Also, exposure to
these absolute maximum ratings for extended periods may adversely affect device reliability. Functional
operation is not implied at these or any other conditions in excess of those represented in the operational
sections of this datasheet. Permanent damage is also possible if any device input (Vc or FS) draws greater
than 100mA.
Suggested Output Load Configurations
+3.3V
0.10 F
+3.3V
0.10 F
+3 .3V
0.01 F
0.01 F
150
150
Vc
1
6 Vcc
COutp ut
FS
2
5
Out put
Gnd
3
4
Z = 50
10 0
Z = 50
240
24 0
LV-PECL to LV-PECL: For short transmission lengths, the power
consumption could be reduced by removing the 100 resistor and
doubling the value of the pull down resistors.
+3.3V
0.10 F
0.01 F
Vc
1
6 Vcc
40
40
COutput Z = 50
FS
2
5
Gnd
3
Output Z = 50
4
49
49
LV-PECL to LVDS: Restricted for short transmission lengths.
Configuration may require modification depending on LVDS receiver.
+2.0V
0.10 F
0.01 F
Vc
1
Vcc
6
COutp ut
FS
2
5
Out put
Gnd
3
4
0.01 F
0.01 F
240
24 0
Functional Test: Allows standard power supply configuration.
Since AC coupled, the LV-PECL levels cannot be measured.
Vc
1
Vcc
6
COutput
FS
2
5
Output
-1.3V
3
4
Production Test: Allows direct DC coupling into 50 measurement
equipment. Must bias the power supplys as shown. Similar to Figure 1.
Vectron International, 267 Lowell Rd, Hudson NH 03051-4916
Page 4 of 7
Tel: 1-88-VECTRON-1 Website: www.vectron.com
Rev: 09Jan06