English
Language : 

EX-209 Datasheet, PDF (4/6 Pages) Vectron International, Inc – Hi-Reliability Evacuated Miniature Crystal Oscillator
Screening Options
Ordering Code
S
B
Test Inspection
S-Level Screening
B-Level Screening
Nondestructive Bond Pull
MIL-STD-883
Method 2023
N/A
Internal Visual Per Mil-PRF-55310
Requirement
Internal Visual Per Mil-PRF-55310
Requirement
Internal Visual Per Mil-PRF-55310
Requirement
Stabilization Bake
MIL-STD-883
Method 1008,
Condition C
150°C for 48hrs
MIL-STD-883
Method 1008,
Condition C
150°C for 48hrs
Thermal Shock
MIL-STD-883
Method 1011,
Condition A
0°C to 100°C for
15cycles
N/A
Temperature Cycling (1)
MIL-STD-883
Method 1010,
Condition A
-55°C to 85°C (2)
for 10cycles
MIL-STD-883
Method 1010,
Condition A
-55°C to 85°C (2)
for 10cycles
Constant Acceleration (1)
MIL-STD-883
Method 2001
1000g’s (3)
Y1 Only
MIL-STD-883
Method 2001
1000g’s (3)
Y1 Only
Seal (Fine & Gross Leak) (1)
N/A (Vacuum Seal)
N/A (Vacuum Seal)
PIND
MIL-STD-883
Method 2020,
Condition B
10g peak at 60Hz
minimum
N/A
Electrical Test
Per Mil-PRF-55310 Requirement
Per Mil-PRF-55310 Requirement
Burn-in (1)
85°C (2) for 240hrs
85°C (2) for 240hrs
Electrical Test
Per Mil-PRF-55310 Requirement
Per Mil-PRF-55310 Requirement
Radiographic
MIL-STD-883
Method 2012
N/A
Note:
(1) These test inspections deviate from screening requirements for class 2 oscillator in MIL-PRF-55310.
(2) The maximum operating and storage temperature of the EX-209 is +85°C. The EX-209 shall not be exposed to temperature higher than
+85°C at length of time.
(3) The design and construction of the EX-209 can withstand up to 1000g’s constant acceleration
http://www.vectron.com
Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1
Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100