English
Language : 

VCB2 Datasheet, PDF (3/6 Pages) Vectron International, Inc – 3.3, 5.0 volt CMOS Oscillator
VCB2 Data Sheet
Table 2. Electrical Performance, 3.3V option
Parameter
Symbol
Frequency
fO
Operating Supply Voltage 1
VDD
Absolute Maximum Operating Voltage
Supply Current, Output Enabled
IDD
0.032786 to 2.0 MHz
2.01 to 30 MHz
30.01 to 50 MHz
50.01 to 160 MHz
Output Logic Levels
Output Logic High2
VOH
Output Logic Low2
VOL
Output Rise/Fall Time2
tR/tF
0.032768 to 2.00 MHz
2.01 to 20.00 MHz
20.01 to 160.00 MHz
Duty Cycle3 (ordering option)
SYM
Operating Temperature (ordering option) TOP
Storage Temperature
Stability4 (ordering option)
Output Enable/Disable5
TSTOR
∆F/T
E/D
Output Enabled
Output Disabled
Start-up time
TSU
Min
0.032768
2.97
-0.5
Typical
3.3
Maximum
160.000
3.63
5.0
8
10
20
35
0.9*VDD
0.1*VDD
12
10
6
40/60 or 45/55
0/70 or –40/85
-55
125
±20, ±25, ±32, ±50, ±100
2.0
0.5
10
Units
MHz
V
V
mA
V
V
ns
%
°C
°C
ppm
V
ms
1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended.
2. Figure 3 defines these parameters. Figure 4 illustrates the operating conditions under which these parameters are tested and
specified. For Fo>90MHz, rise and fall time is measured 20 to 80%.
3. Symmetry is measured defined as On Time/Period.
4. Includes calibration tolerance, operating temperature, supply voltage variations, aging and shock and vibration (not under
operation).
5. Output will be enabled if enable/disable is left open.
VOH
50%
VOL
tR
tF
On Time
Period
IDD
+
VDD -
.1µF
.01µF
4
1
IC
VC +
-
3
2
15pF
Figure 3. Output Waveform
Figure 4. Typical Output Test Conditions (25±5°C)
Vectron International 267 Lowell Rd, Hudson NH 03051 Tel: 1-88-VECTRON-1 e-mail vectron@vectron.com