English
Language : 

TFS71D Datasheet, PDF (3/3 Pages) Vectron International, Inc – Specification
__________________________________________________________________________________
VI TELEFILTER
Specification
TFS 71 D - Page 3/3
__________________________________________________________________________________
6. Environmental Test Conditions
Dry heat:
According to IEC 68 - 2 - 2; + 85 °C; 1000 hours.
Damp heat , steady state: According to IEC 68 - 2 - 3; 92 % rel. humidity; + 40 °C, 21 days.
Damp heat , cyclic :
According to IEC 68 - 2 - 30; 95 % rel. humidity; + 20 °C / + 55 °C within
12 + 12-hour cycle; 6 days.
Vibration (sinusoidal):
According to IEC 68 - 2 - 6; 10 Hz - 500 Hz, 0,075 mm or 1g respectively,
1 octave per min, 10 cycles per plan, 3 plans;
Change of temperature:
According to IEC 68 - 2 - 14 and IEC 68 - 2 - 33; -25 °C / +85 °C, 10 cycles.
Resistance to solder heat: According to IEC 68 - 2 - 20, test Tb, test method 1A; 260 °C; 10 sec.;
Solderability:
According to IEC 68 - 2 - 20; test Ta, test method 1;
soft solder L - Sn60 Pb40;
235 °C / 2 sec.; Flux is Kolophonium 25 % and Propanol 75 % or Ethanol 75 %;
Preconditioning is aging according to IEC 68 - 2 - 30;
95 % rel. humidity; +25 °C / +55 °C within 12 + 12-hour cycle; 6 days.
Absolute maximum ratings
Operating temperature range:- 25 °C / + 85 °C
Storage temperature range: - 40 °C / + 85 °C
Input power level :
0 dBm
Permissible humidity :
≤ 75 % in annual average;
Highest value:
95 % rel. humidity only 30 days within a year, otherwise 85 %; short term
formation of condensation is permissible.
Requirements after Tests
The limiting values of supplier have to be fulfilled. Neither mechanical nor electrical damages should happen.
__________________________________________________________________________________
VI TELEFILTER / Potsdamer Straße 18 / D - 14 513 TELTOW