Parameter
Power Supply
Output Current
Storage Temperature
Soldering Temp/Time
Absolute Maximum Ratings
Symbol
VCC
IOUT
TS
TLS
Ratings
0 to 4
25
-55 to 125
260 / 40
Unit
V
mA
°C
°C / sec
Stresses in excess of the absolute maximum ratings can permanently damage the device. Functional operation is not implied
at these or any other conditions in excess of conditions represented in the operational sections of this datasheet. Exposure to
absolute maximum ratings for extended periods may adversely a ect device reliability. Permanent damage is also possible if OD
or Vc is applied before Vcc.
Suggested Output Load Con gurations
+3.3V
0.10 µF
0.01 µF
OD
1
N/C
2
Gnd
3
Vcc
6
COutput
5
Output
4
240Ω
Z = 50Ω
Z = 50Ω
100Ω
240Ω
LV-PECL to LV-PECL: For short transmission lengths, the power
consumption could be reduced by removing the 100Ω resistor and
doubling the value of the pull down resistors.
+3.3V
0.10 µF
0.01 µF
OD
1
N/C
2
Gnd
3
Vcc
6
COutput Z = 50Ω
5
Output Z = 50Ω
4
+3.3V
150Ω
150Ω
40Ω
40Ω
49Ω
49Ω
LV-PECL to LVDS: Restricted for short transmission lengths.
Configuration may require modification depending on LVDS receiver.
+3.3V
0.10 µF
0.01 µF
OD
1
N/C
2
Gnd
3
Vcc
6
COutput
5
Output
4
240Ω
0.01 µF
0.01 µF
240Ω
Functional Test: Allows standard power supply configuration.
Since AC coupled, the LV-PECL levels cannot be measured.
+2.0V
0.10 µF
0.01 µF
OD
1
N/C
2
-1.3V
3
Vcc
6
COutput
5
Output
4
Production Test: Allows direct DC coupling into 50Ω measurement
equipment. Must bias the power supplys as shown. Similar to Figure 1.
Page3 of 7
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Rev: 02/12/2014