English
Language : 

FX-500_09 Datasheet, PDF (3/7 Pages) Vectron International, Inc – Low Jitter Frequency Translator
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can permanently damage the device. Functional operation is not implied at
these or any other conditions in excess of conditions represented in the operational sections of this data sheet. Exposure to the
maximum ratings for the extended periods may adversely affect device reliability.
Table 2. Absolute Maximum Ratings
Parameter
Symbol
Ratings
Unit
Power Supply
Storage Temperature
V
7
V
DD
T
-55 to 125
0C
STR
Reliability
The FX-500 is capable of meeting the following qualification tests
Table 3. Environmental Compliance
Parameter
Mechanical Shock
Mechanical Vibration
Lead Solderability
Gross and Fine Leak
Conditions
MIL-STD-883, M2002/TEST A
MIL-STD-883, M2007/TESTA
MIL-STD-883, M2003
MIL-STD-883, M1014
Handling Precautions
Although ESD protection circuitrry has been designed into the the FX-424, proper precautions should be taken when handling
and mounting. VI employs a human body model and a charged-device model (CDM) for ESD susceptibility testing and design
protection evaluation. ESD thresholds are dependent on the circuit parameters used to define the model. Although no industry
wide standard has been adopted for the CDM, a standard HBM of resistance=1.5Kohms and capacitance = 100pF is widely used
and therefore can be used for comparison purposes
Table 4. Predicted ESD R$atings
Model
Human Body Model
Charged Device Model
Minimum
1000 V
1000 V
Conditions
MIL-STD 883, Method 3015
JEDEC, JESD22-C101
3 of 7
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Rev: 14Aug2009