English
Language : 

FX-104 Datasheet, PDF (3/12 Pages) Vectron International, Inc – Frequency Translator
Outline Drawing
FX-104 Frequency Translator
Pin Out
Pin
Symbol
1
CLKIN
2
GND
3
LD
(output)
4
Monitor
(Output)
5
---
6
NC
7
GND
8
Enable
Disable
9
Out
10
COUT
11
NC
12
Select A
13
Select B
14
NC
15
GND
16
Vcc
Function
Input Frequency - The FX-104 series AC couples the input, this means the unit is capable of
handling HCMOS, LvHCMOS, PECL and LvPECL input signals.
(For Input Frequencies below 1 MHz only HCMOS and LvHCMOS are supported)
Ground
Lock Detect
Logic “1” indicates a locked condition
Logic “0” indicates that no input signal is present or the input signal has moved out of the
lock range.
PLL/ VCXO control voltage
Under locked conditions, should be >0.3V and <3.0V for the 3.3 volt option or >0.5V and
<4.5V for the 5 volt option. Input frequency may be out of range if voltage exceeds these limits.
Missing
No Connection
Ground
No connect = Output enabled
Logic “0” = Output disabled
Output
Complementary Output
No Connection
Do not Exceed Vcc
Do not Exceed Vcc
No Connection
Ground
Power Supply Voltage (5 Vdc or 3.3Vdc)
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Web: www.vectron.com