English
Language : 

VCE1 Datasheet, PDF (2/5 Pages) List of Unclassifed Manufacturers – VCE1 14 x 9.8 mm Crystal Oscillators
Performance Characteristics
Table 1. Electrical Performance, 5V option
Parameter
Symbol
Frequency
fO
Operating Supply Voltage 1
VDD
Absolute Maximum Supply Voltage
Supply Current, Output Enabled
IDD
Output Logic Levels
Output Logic High2
VOH
Output Logic Low2
VOL
Output Rise/Fall Time2
Duty Cycle3 (ordering option)
Operating Temperature (ordering option)
Storage Temperature
Stability4 (ordering option)
Output Enable/Disable5
Output Enabled
Output Disabled
Start-up time
tR/tF
SYM
TOP
TSTOR
∆F/T
E/D
TSU
Min
1.000
4.5
-0.7
Typical
5.0
Maximum
66.667
5.5
7.0
40
0.9*VDD
-55
40/60 or 45/55
0/70 or -40/85
±50, ±100
0.1*VDD
8
125
4.0
0.8
10
Units
MHz
V
V
mA
V
V
ns
%
°C
°C
ppm
V
ms
Table 2. Electrical Performance, 3.3V option
Parameter
Symbol
Min
Typical Maximum Units
Frequency
Operating Supply Voltage 1
Absolute Maximum Operating Voltage
fO
1.000
VDD
2.97
3.3
-0.5
66.667
3.63
5.0
MHz
V
V
Supply Current, Output Enabled
Output Logic Levels
Output Logic High2
Output Logic Low2
Output Rise/Fall Time2
Duty Cycle3 (ordering option)
IDD
40
mA
VOH
0.9*VDD
V
VOL
0.1*VDD
V
tR/tF
8
ns
SYM
40/60 or 45/55
%
Operating Temperature (ordering option)
TOP
0/70 or –40/85
°C
Storage Temperature
Stability4 (ordering option)
Output Enable/Disable5
TSTOR
-55
∆F/T
E/D
125
±50, ±100
°C
ppm
V
Output Enabled
2.0
Output Disabled
0.5
Start-up time
TSU
10
ms
1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended.
2. Figure 3 defines these parameters. Figure 4 illustrates the operating conditions under which these parameters are
tested and specified. For Fo>90MHz, rise and fall time is measured 20 to 80%.
3. Symmetry is measured defined as On Time/Period.
4. Includes calibration tolerance, operating temperature, supply voltage variations, aging and shock and vibration.
5. Output will be enabled if enable/disable is left open.
tR
tF
ID D
VOH
50%
VOL
On Time
+ .1µF .01µF
VDD -
4
1
IC
VC +
-
23
15pF
Period
Figure 3. Output Waveform
Figure 4. Typical Output Test Conditions (25±5°C)
Vectron International 267 Lowell Rd, Hudson NH 03051 Tel: 1-88-VECTRON-1 e-mail: vectron@vectron.com