English
Language : 

TFS80G Datasheet, PDF (2/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 80g.doc
VI TELEFILTER
Version 1.3
Filter specification
TFS 80G
14.11.2005
2/5
Filter characteristic
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
79.6
79.7
79.8
79.9
80
80.1
80.2
80.3
80.4
80.5
frequency in MHz
0
-5
-10
-15
79.95
79.96
79.97
79.98
79.99
80
frequency in MHz
80.01
80.02
80.03
80.04
Construction and pin connection
(All dimensions in mm)
13,6Max.
TFS 80G
● T46
1
1,5 2,54 ±0,15
1234
12
5
11
6
10 9 8 7
0,8
0,1
Date code
1
Ground
2
Ground
3
Ground
4
Ground
5
Output
6
Output
7
Ground
8
Ground
9
Ground
10
Ground
11
Input
12
Input
Date code:
T
U
V
...
Year + week
2005
2006
2007
100 Ω Test circuit
L1
L3
11
5
L2
C1 12
SAW
6
C2
L4
1, 2, 3, 4, 7, 8, 9, 10
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.