TFS678 Datasheet, PDF (2/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 678.doc
Vectron International
Version 1.5
Filter specification
Filter characteristic
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
0
200 400 600 800 1000 1200 1400 1600 1800
frequency in MHz
0
-0.5
-1
-1.5
-2
-2.5
-3
-3.5
-4
-4.5
-5
650
TFS 678
660
670
680
frequency in MHz
07.01.2014
2/5
690
700
Construction and pin connection
(All dimensions in mm)
7
5
678
● E02
1
3
Date code
2,54
1
3
7
5
1,78
1
Ground
2
Input
3
Ground
4
Ground
5
Ground
6
Output
7
Ground
8
Ground
Date code:
E
F
G
...
Year + week
2014
2015
2016
50 Ω Test circuit
L1
2
6
L2
SAW
1, 3, 4, 5, 7, 8
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com