English
Language : 

TFS618 Datasheet, PDF (2/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 618.doc
Vectron International
Version 1.1
Filter specification
TFS 618
Filter characteristic
insertion loss: -1.89 dB
0
0
-10
-0.5
-20
-1
-30
-1.5
-40
-2
-50
-2.5
-60
-3
-70
-3.5
-80
-4
-90
-4.5
-100
-5
18 138 258 378 498 618 738 858 978 1098 1218
frequency in MHz
Construction and pin connection
(All dimensions in mm)
7
5
1
618
2
3
● A22
4
5
6
7
1
3
8
Date code
600
610
620
630
frequency in MHz
Ground
Input
Ground
Ground
Ground
Output
Ground
Ground
28.05.2010
2/5
0.42
0.372
0.324
0.276
0.228
0.18
0.132
0.084
0.036
-0.012
-0.06
640
2,54
1
3
7
5
1,78
Date code:
A
B
C
...
Year + week
2010
2011
2012
50 Ω Test circuit
L1
2
6
L2
SAW
1, 3, 4, 5, 7, 8
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.