English
Language : 

TFS465K Datasheet, PDF (2/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: TFS465K.doc
Vectron International
Version 1.3
Filter specification
TFS 465K
23.10.2012
2/5
Filter characteristic
insertion loss: -9.87 dB
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
365
385
405
425
445
465
485
505
525
545
565
frequency in MHz
0
0.51
-0.5
0.486
-1
0.462
-1.5
0.438
-2
0.414
-2.5
0.39
-3
0.366
-3.5
0.342
-4
0.318
-4.5
0.294
-5
455.21
457.21
459.21
461.21
463.21 465.21 467.21
frequency in MHz
469.21
471.21
473.21
0.27
475.21
Construction and pin connection
(All dimensions in mm)
7
5
465K
● B24
1
3
Dat e code
2,54
1
3
7
5
1,78
1
Input
2
Input RF Return
3
Ground
4
Ground
5
Output
6
Output RF Return
7
Ground
8
Ground
Date code:
A
B
C
...
Year + week
2010
2011
2012
50 Ω Test circuit
L1
L2
1
5
2 SAW 6
3,4,7,8
L3
L4
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without