English
Language : 

TFS434K Datasheet, PDF (2/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: TFS434K.doc
Vectron International
Version 1.1
Filter specification
TFS 434K
06.08.2013
2/5
Filter characteristic
insertion loss: -10.86 dB
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
334
354
374
394
414
434
454
474
494
514
534
frequency in MHz
0
0.54
-1
0.5112
-2
0.4824
-3
0.4536
-4
0.4248
-5
0.396
-6
0.3672
-7
0.3384
-8
0.3096
-9
0.2808
-10
424.23
426.23
428.23
430.23
432.23 434.23 436.23
frequency in MHz
438.23
440.23
442.23
0.252
444.23
Construction and pin connection
(All dimensions in mm)
7
5
434K
● D24
1
3
Dat e code
1
Input
2
Input RF Return
3
Ground
4
Ground
5
Output
6
Output RF Return
7
Ground
8
Ground
2,54
1
3
7
5
1,78
Date code:
D
E
F
...
Year + week
2013
2014
2015
50 Ω Test circuit
L1
C1
1
5
2
SAW
6
3, 4, 7, 8
L2
C2
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.