English
Language : 

TFS400P Datasheet, PDF (2/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 400p.doc
Vectron International
Version 1.1
Filter specification
TFS 400P
06.11.2009
2/5
Filter characteristic
0
insertion loss: -11.11 dB
-7
-14
-21
-28
-35
-42
-49
-56
-63
-70
355
364
373
382
391
400
409
418
427
436
445
frequency in MHz
0
0.762
-1
0.714
-2
0.666
-3
0.618
-4
0.57
-5
0.522
-6
0.474
-7
0.426
-8
0.378
-9
0.33
-10
0.282
390
392
394
396
398
400
402
404
406
408
410
frequency in MHz
Construction and pin connection
(All dimensions in mm)
9,1+- 00,,21
TFS 400P 5
● X45
1
3
5,08
1
3
Date code
1
Input
2
Input RF Return
3
Ground
4
Ground
5
Ground
6
Output
7
Output RF Return
8
Ground
9
Ground
10
Ground
8
0,8
6
1
Date code:
X
A
B
...
Year + week
2009
2010
2011
50 Ω Test circuit
L1
C1
1
6
2
SAW
7
3, 4, 5, 8, 10
L2
C2
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.