English
Language : 

TFS400M Datasheet, PDF (2/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 400m.doc
VI TELEFILTER
Version 1.2
Filter specification
TFS 400M
31.08.2007
2/5
Filter characteristic
0
-6
Filter characteristic
-12
-18
-24
-30
-36
-42
-48
-54
-60
350
360
370
380
390
400
410
420
430
440
450
frequency in MHz
0
0.762
-1
0.714
-2
0.666
-3
0.618
-4
0.57
-5
0.522
-6
0.474
-7
0.426
-8
0.378
-9
0.33
-10
0.282
390
392
394
396
398
400
402
404
406
408
410
frequency in MHz
Construction and pin connection
(All dimensions in mm)
7
5
400M
● V35
1
3
Date code
1
Input
2
Input
3
Ground
4
Ground
5
Output
6
Output
7
Ground
8
Ground
1
3
75
1,1
2,54
200 Ω Test circuit
Date code:
V
W
X
...
Year + week
2007
2008
2009
1
L1
C1
L2
2
5
SAW
6
3, 4, 7, 8
L3
C2
L4
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is