English
Language : 

TFS380L Datasheet, PDF (2/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 380l.doc
VI TELEFILTER
Version 1.0
Filter specification
TFS 380L
15.02.2005
2/5
Filter characteristic
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
360.6 364.4 368.2 372 375.8 379.6 383.4 387.2 391 394.8 398.6
frequency in MHz
0
1.58
-1
1.49
-2
1.4
-3
1.31
-4
1.22
-5
1.13
-6
1.04
-7
0.95
-8
0.86
-9
0.77
-10
0.68
374.6 375.6 376.6 377.6 378.6 379.6 380.6 381.6 382.6 383.6 384.6
frequency in MHz
Construction and pin connection
(All dimensions in mm)
S 380L
● T07
1
3
Date cod e
7,2 Max.
2,54 ±0,2
1
1
Ground
2
Ground
3
Output RF Return
4
Output
5
Ground
6
Ground
7
Ground
8
Ground
9
Input RF Return
10
Input
11
Ground
12
Ground
Date code:
T
U
V
...
Year + week
2005
2006
2007
0,80
50 Ohm Test circuit
L1
C1
10
4
9
SAW 3
1, 2, 5, 6, 7, 8, 11, 12
L2
C2
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is