English
Language : 

TFS190S Datasheet, PDF (2/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 190s.doc
VI TELEFILTER
Version 1.3
Filter specification
TFS 190S
10.10.2006
2/5
Filter characteristic
0
-8
-16
-24
-32
-40
-48
-56
-64
-72
-80
170
174
178
182
186
190
194
198
202
206
210
frequency in MHz
0
2.47
-1
2.35
-2
2.23
-3
2.11
-4
1.99
-5
1.87
-6
1.75
-7
1.63
-8
1.51
-9
1.39
-10
188
188.4
188.8
189.2
189.6
190
190.4
frequency in MHz
190.8
191.2
191.6
1.27
192
Construction and pin connection
(All dimensions in mm)
13,3 ±0,2
TFS 190S
●
Date code
1
Input RF Return
2
Ground
3
Ground
4
Ground
5
Output
6
Output RF Return
7
Ground
8
Ground
9
Ground
10
Input
1 1,0±0,2 5
1,91±0,2
10 7,62±0,2 6
Date code:
U
V
W
...
Year + week
2006
2007
2008
50 Ω Test circuit
L
C
10
5
SAW
1
6
2, 3, 4, 7, 8, 9
L2
C2
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.