English
Language : 

AR-51-09 Datasheet, PDF (2/8 Pages) Vectron International, Inc – GPS-Disciplined Rubidium Clock
Performance SpecificaƟons
All specifica ons are at room temperature, quiescent condi ons, sea level ambient unless otherwise specified
Outputs(*)
Input & Outputs
10MHz, Sine wave (8±3) dBm / 50Ω (x 1)
1PPS TTL/50Ω (x 2)
1PPS RS-422 (x 5)
1PPS PTTI (ICD-GPS-060)/ 50Ω (x 17)
TOD Have Quick (ICD-GPS-060) / TTL 100KΩ (x 4)
Input
CLI
CommunicaƟon
MIL-GPS Keys
H/W BIT (open collector) (x 1)
TOD Have Quick (ICD-GPS-060) / TTL 100K Ω (x 1)
1PPS TTL/50Ω or PTTI, ICD-GPS-060/ 50Ω (x 1)
1PPS RS-422 (x 1)
GPS Antenna
CLI – Command Line Interface, RS232 or RS422 for status monitoring and control
for unit configura on
Baud rate: 19,200, Control: 1, N, 8
Op ons: NMEA, NTP server V3 per RFC1305 ≤ 1ms, IEEE 1588 (PTP) –
Grandmaster, IRIG B
Op ons: NMEA, IEEE 1588 (PTP) – Slave, IRIG B
Op ons: LAN – UDP & SNMP, MIL- STD-1553RT (Mux-Bus)
Op on: P (Y) code GPS receiver crypto keys
(*) For other outputs contact factory
MuxBus/LAN/IRIG B
AUX COM
(op on)
(RS-422)
GPS Ant.
1PPS IN#1, ICD-GPS-060
1PPS IN#2, RS-422
TOD (HQ) IN, ICD-GPS-060
P(Y) Code GPS keys x6
Power Supply
J3
(TNC)
J5
(SMA)
J4
(SMA)
J1 / J2 J1 / J2 x17
x1
AR51A-09 x5
x4
10MHz OUT
1PPS OUT (TTL)
1PPS OUT, ICD-GPS-060
1PPS OUT, TTL
1PPS OUT, RS-422
TOD (HQ) OUT, ICD-GPS-060
Discrete outputs BIT Indica ons
Open collector/Ground
Discrete Over All BIT
Rb Test point (factory use)
CLI
CLI
(RS-422) (RS-232)
Electrical Interface
Page 2 of 8
Vectron Interna onal • 267 Lowell Road, Suite 102, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • h p://www.vectron.com