TM-056 Datasheet, PDF (1/7 Pages) Vectron International, Inc – Integrated Timing Solution | |||
|
TM-056
Integrated Timing Solution
The TM-056 is a compact Timing Module, which functions as a complete system clock solution for general Stratum 3 timing applications. The
TM-056 uses Vectronâs Digital and Analog Phase Locked Loop (DPLL and APLL) technology and can lock to 2 reference frequencies automatically.
The module has dual output clocks ranging from 8 kHz to 77.76 MHz. Simple control interface with comprehensive state engine, status and
alarm indications and fully automatic operation makes seamless system integration of the TM-056 module.
Features
Applications
⢠Single module Statum 3 synchronization solution.
⢠Complies with Telcordia GR-1244/GR-253 and ITU-T G.812/G.813
recommendations.
⢠Supports Free-run, Holdover and Lock modes.
⢠Accepts 2 reference inputs from frequency range 8kHz to 77.76MHz.
⢠Continuously monitors and evaluates both input reference signals
simultaneously.
⢠Provides two synchronized outputs with frequency range up to 77.76MHz.
⢠On board OCXO that provides excellent stability in Freerun and Holdover
mode.
⢠Loop filtering utilizing DPLL.
⢠Automatic âhit-lessâ switchover on loss of input.
⢠Holdover mode with 90 seconds of history.
⢠Alarms and status signals.
⢠Easy to use control interface and JTAG port for factory programming.
⢠Small dimensions 1.9â x 1.9â x 0.55â.
⢠Product is compliant to RoHS directive and fully compatible with lead free
assembly.
⢠Multi-service Switches and Routers
⢠ATM
⢠Gateway
⢠Access
⢠EDGE
⢠Core
⢠SONET
⢠SDH
⢠DWDM
Block Diagram
OCXO
EX REF 1
EX REF 2
Reference
Monitor
and
Selection
DPLL
APLL
Output
Dividers
OUT 1
OUT 2
CNT 1
CNT 2
CPU
HOLDOVER
REF 1
REF 2
FREERUN
ALARM
UNLOCK
Vectron International ⢠267 Lowell Road, Hudson, NH 03051 ⢠Tel: 1-88-VECTRON-1 ⢠http://www.vectron.com
|
▷ |