English
Language : 

TFS935 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 935.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.3
Filter specification
23
°C
0
dBm
50
Ω
50
Ω
TFS 935
25.05.2005
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 935 MHz without any tolerance or limit.
The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
Nominal frequency
Passband
Absolute attenuation
929
MHz ...
0,3 MHz ...
874
974
1019
MHz ...
MHz ...
MHz ...
1031
MHz ...
Input power level
941
874
902
1019
1031
1500
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
ae
fN
aabs
MHz
MHz
MHz
MHz
MHz
MHz
OTR
TCf *
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
typ. value
1,6 dB
-
-
1,6
45
35
53
52
42
-
-
-
-46
dB
dB
dB
dB
dB
dB
ppm/K
tolerance / limit
max.
2,5 dB
935
MHz
fN ±
6
MHz
max.
min.
min.
min.
min.
min.
max.
2,5 dB
40 dB
30 dB
40 dB
50 dB
40 dB
23 dBm
- 30 °C ... + 70 °C
- 40 °C ... + 100 °C
-
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.