English
Language : 

TFS915F Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 915f.doc
VI TELEFILTER
Version 1.1
Filter specification
TFS 915F
10.06.2005
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
°C
0
dBm
50
Ω
50
Ω
Source:
Load:
128 Ω || -2,5 pF
128 Ω || -2,5 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 915F is the minimum attenuation in the pass band. The minimum attenuation in the pass
band is defined as the insertion loss ae. The nominal frequency fN is fixed at 915 MHz without any tolerance or limit. The frequency shift of the filter in the
operating temperature range is included in the production tolerance scheme.
Data
Insertion loss
Nominal frequency
Passband
Amplitude ripple
Relative attenuation
932
MHz
Input power level
Operating temperature range
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
ae
fN
PB
within PB
arel
OTR
TCf *
typ. value
3,2 dB
-
-
0,5 dB
37
dB
-
-
-
25
°C
- 0,036 ppm/K²
tolerance / limit
max.
6 dB
915
MHz
fN ±
max.
0,4 MHz
3,5 dB
min.
max.
30
dB
10 dBm
- 10 °C ... + 55 °C
- 40 °C ... + 85 °C
-
-
*) ∆fc(Hz) = Tcf(ppm/K²) x (T - To)² x fCAT (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.