English
Language : 

TFS915D Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 915d.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.2
Filter specification
23
°C
0
dBm
50
Ω
50
Ω
TFS 915D
14.12.2006
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 915,0 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
ae
Insertion loss in OTR2
Nominal frequency
fN
Passband
PB
Absolute attenuation
0,3
928
928
935
MHz
MHz
MHz
MHz
… 880
… 935
… 935
… 1900
MHz
MHz
MHz
MHz
aabs
in OTR2
Input power level
Operating temperature range
OTR
Operating temperature range 2
Storage temperature range
Temperature coefficient of frequency
OTR2
TCf *
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
typ. value
2,7 dB
-
-
12,5 MHz
44
dB
34
dB
-
43
dB
-
-
-
-37
ppm/K
tolerance / limit
max.
max.
3,0 dB
3,5 dB
915,0 MHz
fN
± 3,5 MHz
min.
40 dB
min.
16 dB
min.
12 dB
min.
40 dB
max.
10 dBm
- 10 °C ... + 60 °C
- 40 °C ... + 85 °C
- 40 °C ... + 85 °C
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.