English
Language : 

TFS887 Datasheet, PDF (1/5 Pages) Vectron International, Inc – VI TELEFILTER Filter specification
Filename: tfs 887.doc
Vectron International
Version 2.2
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
°C
0
dBm
50
Ω
50
Ω
TFS 887
09.08.2013
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 887 is the minimum of the pass band attenuation. This value is defined as the insertion loss
ae. The nominal frequency fN is fixed at 887.0 MHz without any tolerance. The values of relative attenuation arel are guaranteed over the whole operating
temperature range. The frequency shift of the filter within the operating temperature range is included in the production tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss
Nominal frequency
ae
3.3 dB
fN
-
max.
4.0 dB
887.0 MHz
Passband
Pass band variation
PB
-
1.2 dB
fN ± 14.0 MHz
max.
1.5 dB
Relative attenuation
arel
0.3
689
MHz ... 689
MHz … 717
MHz
MHz
43
dB
42
dB
min.
20 dB
min
40 dB*
717
MHz … 836
MHz
27
dB
min
20 dB
925
MHz … 945
MHz
16
dB
min
0 dB
945
MHz … 2000 MHz
43
dB
min
25 dB
Input power level
-
max.
17 dBm
Operating temperature range
OTR
-
-40 °C ... + 85 °C
Storage temperature range
-
- 40 °C ... + 85 °C
Temperature coefficient of frequency
TCf **
-76
ppm/K
*) single spurious resonance in this band allowed (typically at fN – 189.5MHz), 3dB band width <320kHz, relative attenuation min. 36dB (typical 38dB).
**) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz)
Generated:
Checked / Approved:
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.