English
Language : 

TFS846 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 846.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.2
Filter specification
23
°C
0
dBm
50
Ω
50
Ω
TFS 846
19.04.2006
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 846 MHz without any tolerance or limit.
The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss in PB1
Insertion loss in PB2
Nominal frequency
Centre frequency
Passband 1
Pass band ripple
Passband 2
Absolute attenuation
750
880
1000
1200
1550
MHz
MHz
MHz
MHz
MHz
… 800
… 915
… 1100
… 1250
… 1600
VSWR within PB1
Input power level
MHZ
MHZ
MHZ
MHZ
MHZ
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
ae
ae2
fN
fC
PB1
PB2
aabs
OTR
TCf *
*) ∆ f(Hz) =TCf(ppm/K) x(T-T0) x fTo (MHz)
typ. value
1,6
2,2
-
846
-
0,9
-
dB
dB
MHz
dB
28
dB
32
dB
31
dB
31
dB
38
dB
2,1 : 1
-
-
-
- 46
ppm/K
tolerance / limit
max.
max.
2,3
3,0
846
-
fN
± 13,5
max.
1,5
fN
± 16,0
dB
dB
MHz
MHz
dB
MHz
min.
25 dB
min.
25 dB
min.
26 dB
min.
26 dB
min.
20 dB
max.
2,2 : 1
max.
15 dBm
- 30 °C ... + 70°C
- 40 °C ... + 85°C
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.