TFS 80 D2 - 1/4
1. Measurement condition :
Ambient temperature TA:
Input power level:
Terminating impedances in fc:
23 °C
0 dBm.
for input:
for output:
50 Ω  - 56 pF
50 Ω  0 pF,
2. Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 80 D2 is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower
frequencies at the 3 dB filter attenuation level relative to the insertion loss ae.
Data
Insertion loss (Reference level) ae
Centre frequency
fc at ambient temperature ( fCAT )
Pass band (-3 dB)
Bandwidth at ambient temperature:
3 dB - band width
10 dB - band width
20 dB - band width
36 dB - band width
45 dB - band width
Relative attenuation arel
fc ... fc ± 100 kHz
fc - 400 kHz .... fc - 200 kHz
fc + 200 kHz ... fc + 400 kHz
fc ± 400 kHz ... fc ± 500 kHz
fc ± 500 kHz ... fc ± 1,0 MHz
fc ± 1,0 kHz ... fc ± 35 MHz
Group delay ( mean value in PB ):
Group delay ripple :
fc – 100 kHz .....fc
fc ... fc + 100 kHz
Deviation from linear phase in PB (p-p):
Triple transit attenuation compared to main signal
Crosstalk
typ. value
14,0 dB
80,07 MHz
tolerance / limit
max. 14,5 dB
80,07 ± 0,01 MHz
fC- 100 kHz ... fC + 100 kHz
212 kHz
350 kHz
450 kHz
770 kHz
990 kHz
min. 200 kHz
max. 800 kHz
max.1000 kHz
--
--
--
40 dB
50...60 dB
60...70 dB
4,12 µs
500 ns
700 ns
5,2°
33...34 dB
55...60 dB
max.
min.
min.
min.
min.
min.
3 dB
11 dB
19 dB
36 dB
45 dB
50 dB
max. 600 ns
max. 750 ns
Frequency inversion temperature ( To )
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fc over temperature: * )
Operating temperature range
Storage temperature range
10°
-0,045 ppm/K²
∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz)
- 25 °C ... + 75 °C
- 30 °C ... + 85 °C
* ) fTo is reference frequence fc at frequency inversion temperature (To )
Generated:
Checked/Approved:
Dunzow W.
Dr. Bert Wall
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.