English
Language : 

TFS80A Datasheet, PDF (1/3 Pages) Vectron International, Inc – Filter specification
t_fs_8_0_a_.d_o_c_________________________________________________________v_e_rs_i_on__1_.2_________0_6_.0_1_._02_________________
V__I__T_E__L_E__F_I_L__T_E__R_______________________F__i_lt_e__r_s__p_e_c__i_fi_c_a__t_io__n___________T__F_S___8__0__A___-__P__a_g__e__1__/_3_____
Measurement condition
Ambient temperature: 23 °C
Input power level:
0 dBm
Termination impedance:
Input:
110 Ω || - 18 pF
Output:
50 Ω || - 13 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 80 A is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the
3dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 80,0 MHz without tolerance. The given values for
the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted
due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo
Data
typ. value
tolerance / limit
______________________________________________________________________________________________________
Insertion loss
ae
-
max. 16,5 dB
(Reference level)
______________________________________________________________________________________________________
N__o_m__in_a_l_f_re_q__u_e_n_c_y_______fN____________________________________-_____________________________8_0_,0_____M_H_z_____
P__a_s_s_b_a_n_d___________________________________________________-_____________________f_N__- _1_0_0_k_H_z__.._._fN__+__1_0_0_k_H_z
Relative attenuation
arel
fN - 100 kHz ... fN + 100 kHz
-
max 1
dB
fN ± 500 kHz
-
min 35
dB
fN ± 600 kHz
-
min 40
dB
fN ± 700 kHz
-
min 45
dB
fN ± 1000 kHz
-
min 50
dB
f_N__±___5_0_0_0___k_H_z_._..__f_N__±___2_5___M_H_z_____________________________-_________________________m_i_n__5_5______d_B______
Group delay
GD
Absolute delay fN - 100 kHz ... fN + 100 kHz
4,55 µs
max 4,85 µs
R__ip_p_l_e__________fN___- _1_0_0_k_H__z_.._._f_N__+_1_0_0__k_H_z_____________________-________________________m__a_x_6_0_0______n_s______
Impedance
Z
Source impedance
110 Ω // - 18 pF
-
Load impedance
280 Ω // - 13 pF
-
______________________________________________________________________________________________________
T__e_m_p_e_r_a_t_u_re__c_o_e_f_fi_c_ie_n_t_o__f _fr_e_q_u_e_n_c_y________T_C_f__*)______________-__0_,0_4_5__p_p_m__/K__² ___________________-_____________
F__re_q_u__e_n_c_y_i_n_v_e_rs_i_o_n__te_m__p_e_r_a_tu_r_e___________T_o__________________2_3_____°_C________________________-_____________
Operating temperature range
- 20 °C ... + 85 °C
Storage temperature range
- 40 °C ... + 85 °C
______________________________________________________________________________________________________
Permissible DC voltage VDC
-
12
V
P__e_rm__i_s_s_ib_l_e_A_C__v_o_l_ta_g__e___V_p_p__________________________________-_____________________________1_0______V_______
*) ∆f(Hz) = TCf(ppm/K²) x (∆T)² x fTo(MHz)
Generated:
Checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.