English
Language : 

TFS800B Datasheet, PDF (1/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 800b.doc
Vectron International
Version 2.1
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
°C
0
dBm
150 Ω || 0 pF
150 Ω || 0 pF
TFS 800B
25.04.2013
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 800.00 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
Nominal frequency
Centre frequency
ae
2.5 dB
f NB
B
-
f CB
B
800.0 MHz
Bandwidth
3 dB
BW
28
MHz
Absolute attenuation
@ 100
@ 200
@ 300
@ 400
@ 500
@ 600
@ 700
@ 900
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
aabs
64
dB
67
dB
68
dB
68
dB
66
dB
67
dB
58
dB
60
dB
Input power level
-
Operating temperature range
OTR
-
Storage temperature range
-
Temperature coefficient of frequency
TCf *
-73
ppm/K
*)
∆f(Hz)
=
TCf(ppm/K)
x
(T
-TB0
)
B
x
fTo(MHz).
Material:
LiNbO3_64° black,
so
in
principle
pyrofree.
tolerance / limit
max.
4.5 dB
800.0
-
MHz
-
min.
50
min.
50
min.
50
min.
50
min.
50
min.
50
min.
50
min.
50
max.
10
-40 °C ... +90 °C
-45 °C ... +95 °C
-
dB
dB
dB
dB
dB
dB
dB
dB
dBm
Generated:
Checked / Approved:
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.