English
Language : 

TFS800A Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 800a.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.0
Filter specification
23
°C
0
dBm
50
Ω
50
Ω
TFS 800A
30.11.2004
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 800 MHz without any tolerance or limit.
The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
Nominal frequency
Passband
Pass band ripple
Absolute attenuation
0,3
820
881
1200
MHz ...
MHz ...
MHz ...
MHz ...
VSWR within PB
Input power level **
ae = amax
fN
PB
770
836
1200
2000
MHz
MHz
MHz
MHz
aabs
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
OTR
TCf *
typ. value
1,7 dB
-
-
0,5 dB
43
dB
44
dB
48
dB
33
dB
1,8 : 1
-
-
-
-42
ppm/K
tolerance / limit
max.
3,0 dB
800,0 MHz
fN ±
max.
6,0 MHz
1,0 dB
min.
min.
min.
min.
max.
max.
40
10
40
20
2,2 : 1
10
dB
dB
dB
dB
dBm
- 30 °C ... + 70 °C
- 40 °C ... + 85 °C
-
*) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fo (MHz).
**) also guaranteed are 27dBm for 48 hours
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.