English
Language : 

TFS76F Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 76f.doc
VI TELEFILTER
Version 1.2
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
0
dBm
498 Ω || -41,1 pF
493 Ω || -47,7 pF
TFS 76F
03.05.2006
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 76F is the minimum of the pass band attenuation. This value is defined as the insertion loss
ae. The nominal frequency fN is fixed at 76,5 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating
temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss
(reference level)
Nominal frequency
Pass band
Pass band ripple
ae
11,8 dB
fN
-
PB
4,1 MHz
p-p
0,6 dB
max.
12,8 dB
fN
max.
76,5
± 1,89
1,3
MHz
MHz
dB
Bandwidth
1,5 dB
3 dB
15 dB
30 dB
Mean relative attenuation
86,47 MHz ...
arel
91,53 MHz
4,2 MHz
4,6 MHz
5,9 MHz
6,8 MHz
54
dB
max.
max.
-
-
6,0 MHz
6,9 MHz
min.
46,0 dB
Relative attenuation
74,61 MHz ...
arel
78,39 MHz
0,6 dB
max.
1,3 dB
50,00
65,44
70,44
81,26
82,56
86,47
91,53
95,21
MHz ...
MHz ...
MHz ...
MHz ...
MHz ...
MHz ...
MHz ...
MHz ...
65,44
70,44
72,04
82,56
86,47
91,53
95,21
100,00
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
50
dB
41
dB
35
dB
39
dB
42
dB
57
dB
60
dB
62
dB
min.
37,0 dB
min.
35,0 dB
min.
33,0 dB
min.
32,0 dB
min.
39,0 dB
min.
40,0 dB
min.
46,0 dB
min.
46,0 dB
Group delay ripple in PB
Input power level
p-p
130
ns
-
max.
-
10 dBm
Operating temperature range
OTR
-
-40 °C ... + 85 °C
Storage temperature range
-
-40 °C ... + 85 °C
Temperature coefficient of frequency
TCf **
-18
ppm/K
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = TCf(ppm/K) x (T - To) x fTo (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.